EVO Rack/Tower 2KVA

Part Number: EVO2000RT-MM

High Reliability:

Online double conversion, 0.99 input power factor, wide voltage (110-286Vac) & frequency range.

Energy-Saving & Compatibility:
ECO mode operation to reduce energy consumption.
Comprehensive Protection & Convenience:
Overload, overheating, short-circuit protection, intelligent cooling, and multiple interfaces.
  • Recommended for Data Centers, Local Area Network (LAN ), Electro-medical, Industry processes, Virtual servers, Pellet stoves, Thermo-fireplaces, Boilers for home heating
  • Intelligent slot for SNMP card o Dry Contact
  • Compatibility with generating set
  • Battery charging system managed by microprocessor
  • Frequency converter mode
  • Convertible format (Rack 19″ or Tower) with adjustable display
  • Hot Swap batteries
 
MODEL

EVO1000RT-MM

EVO2000RT-MM

EVO3000RT-MM

Capacity

1000VA/ 900W

2000VA/ 1800W

3000VA/ 2700W

INPUT
Nominal voltage

208/220/230/240Vac

Input voltage range

110~300Vac (176~280Vac @ 100% load)

Frequency range

40~70Hz  (50/60Hz Auto-Sensing)

Power factor

≥0.99

OUTPUT
Output voltage

208/220/230/240Vac

Power factor

0.9

Voltage regulation

±1%

Output frequency Line Mode

46~54Hz or 56~64Hz

Bat. Mode

(50/60±0.1%)Hz

Crest factor

3:01

Harmonic distortion (THDv)

≤3% Linear load

≤5% Non linear load

Transfer time AC mode to Bat.Mode

0ms

Inverter to Bypass

4ms (Typical)

Output waveform

Pure Sinewave

EFFICIENCY
AC mode

89%

91%

92%

Battery mode

85%

87%

88%

BATTERY

Battery number

2 4

6

Capacity (Standard unit)

9Ah/12V

Typical recharging time

4 hours (to 90% of full capacity)

Charging voltage

27.4Vdc±1%

54.8Vdc±1%

109.6Vdc±1%

Charging current (Max)

1Ah

INDICATORS
LED display

Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault

LCD display

Input voltage,Input frequency,Output voltage,Output frequency,Load percentage,

Battery voltage,Inner temperature& Remaining battery backup time

ALARM
Battery mode

Beeping every 4 seconds

Battery low

Beeping every second

Overload

Beeping twice every second

Fault

Continously beeping

PHYSICAL
Dimension W x D×H (mm)

440 x 325 x 86.5

440 x 460 x 86.5

440 x 600 x 86.5

Net weight (kg)

11.3

19.6

26.2

ENVIRONMENT
Operating temperature

0℃~40℃

Storage temperature

-25℃~55℃

Humidity range

20~95%RH @ 0~40℃ (Non condensing)

Altitude

<1500m,derating required when>1500m

Noise level

<50db at 1 Meter

STANDARDS
Safety

IEC/EN62040-1,IEC/EN62477-1

EMC

IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

Scroll To Top
Close
Close