EVD Tower 3/1 TT 30KVA
Part Number: TLEVD30
High Reliability:
Online double conversion, 0.99 input power factor
Three-phase Input 400Vac, Single-phase Output 230VacEnergy-Saving & Compatibility:
ECO mode operation to reduce energy consumption.
Comprehensive Protection & Convenience:
Overload, overheating, short-circuit protection, intelligent cooling, and multiple interfaces.
- Recommended for Data Centers, Local Area Network (LAN ), Electro-medical, Industry processes, Virtual servers, Pellet stoves, Thermo-fireplaces, Boilers for home heating
- Intelligent slot for SNMP card o Dry Contact
- Compatibility with generating set
- Battery charging system managed by microprocessor
- Frequency converter mode
MODEL | TLEVD10 | TLEVD15 | TLEVD20 | TLEVD30 |
Capacity (VA/Watts) | 10k / 9k | 15k / 13.5k | 10k / 18k | 30k / 27k |
INPUT | ||||
Nominal voltage | 380/400/415Vac, (3Ph+N+PE) | |||
Operating voltage range | 138~485Vac for 40%load; 305~485Vac for full-load | |||
Operating frequency range | 40~70Hz | |||
Power factor | ≥0.99 | |||
Bypass voltage range | 220Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 230Vac Max.voltage: +20%(optional +10%,+15% ) 240Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%) Frequency synchronize tracing range: ±10% |
|||
generator input | Support | |||
Harmonic distortion (THDi) | ≤3%(100% non-linear load) |
OUTPUT | ||
Rated voltage | 220/230/240Vac,(P-N) | |
Power factor | 0.9 | |
Voltage regulation |
±1% | |
Frequency | Line mode | synchronize with input; when input frequency >±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz |
Bat. mode | 50/60(±0.1)Hz | |
Crest factor | 3:1 | |
Harmonic distortion (THDv) | ≤2% with linear load ≤4% with non-linear load |
|
Efficiency | 96% |
BATTERY | ||||
Battery voltage | ±96/108/120Vdc; battery quantity (16~20 pcs, 16 pcs define, Standard unit and 20 pcs no power derating; 18 pcs output power factor 0.8/0.9; 16 pcs output power factor 0.7/0.8;) | |||
Charging current (A)(Charging current can be set according to battery capacity installed) |
14A (Max.) | 16A (Max.) | 18A (Max.) | 20A (Max.) |
SYSTEM FEATURES | |
Transfer time | Utility to Battery : 0ms; Utility to bypass: 0ms |
Overload | ≤110% overload 60 min; ≤150% overload 1 min,to Bypass Bypass mode:135% overload long time; >1000% overload 100 ms |
Backfeed protection | Support |
Alarm | Overload, utility abnormal, UPS fault, battery low, etc. |
Protection | Short circuit, overload, over temperature, battery low, fan fault alarm. |
Remote LCD | Support |
Communication interface |
USB, RS232, RS485, Parallel port, dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional) |
ENVIRONMENT | |||||
Operating temperature | 0~40℃ | ||||
Storage temperature |
25~55℃(No battery) | ||||
Humidity range | 0~95% (Non-condensing) | ||||
Altitude | <1500m. When >1500m, derating power for use | ||||
Noise level | <55db | <58dB | <61dB | ||
PHYSICAL | |||||
Dimension D×W×H (mm) |
828×250×868 | ||||
Net weight (kg) | 57 | 63 | 64 | 71 | |
STANDARDS | |||||
Safety | IEC/EN62040-1,IEC/EN60950-1 | ||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |