EVD Tower 3/1 TT 10KVA

Part Number: TLEVD10

High Reliability:

Online double conversion, 0.99 input power factor

Three-phase Input 400Vac, Single-phase Output 230Vac
Energy-Saving & Compatibility:
ECO mode operation to reduce energy consumption.
Comprehensive Protection & Convenience:
Overload, overheating, short-circuit protection, intelligent cooling, and multiple interfaces.
  • Recommended for Data Centers, Local Area Network (LAN ), Electro-medical, Industry processes, Virtual servers, Pellet stoves, Thermo-fireplaces, Boilers for home heating
  • Intelligent slot for SNMP card o Dry Contact
  • Compatibility with generating set
  • Battery charging system managed by microprocessor
  • Frequency converter mode
 
MODEL TLEVD10-RT TLEVD15-RT TLEVD20-RT
Capacity (VA/Watts) 10k/10k  15k/15k 20k/20k
INPUT 
Nominal Voltage 380/400/415 (3Ph+N+PE)
Operating voltage range 138~485Vac for 40%load; 305~485Vac for full-load
Operating frequency range 40~70Hz
Power Factor ≥0.99
Harmonic distortion (THDi) ≤3% (100% linear load)
 Bypass input 
Bypass voltage range Max. voltage:220V: +25%(optional +10%,+15%,+20% ) ;
230V: +20%(optional +10%,+15% ) ;
240V: +15%(optional +10%)
Min. voltage: -45% (optional -10%,-20%,-30%)
Bypass Frequency range Frequency protection range: ±10%
Generator input Support
OUTPUT  
Output Voltage 220/230/240Vac,(P-N)
Power Factor 1.0
Output frequency(Hz) Line mode:Synchronize with input ;when input frequency >±10%%(±1%、±2%、±4%、±5% Optional,
Output frequency 50×(1±0.1%)Hz Battery mode :(50/60±0.1%)Hz
Waveform Pure sine wave
Crest factor 3:1
Harmonic distortion(THDV) ≤2%(100% linear load); ≤4% (100% non linear load)
Transfer Time(ms) 0 Ms
Efficiency UP to 95
Overload ≤110% overload for 60 min; 125% overload for 10 min; ≤150% overload for 1 min
Bypass Mode 135% overload for long term; >1000% overload for 100 ms
BATTERY
Battery Voltage For optional : Optional Voltage: ±180/192/204/216/228/
240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/
46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 30 pcs default, 36~50 pcs fully output ; 32~34 pcs
Out put power factor 0.9; 30 pcs output power factor 0.8;)
Max charger current (A) 18 20
 Others
 Alarm function     Overload、utility abnormal、UPS fail、battery low voltage etc
 Protection function  Short circuit、overload、overheat、battery low、output low voltage、fan fault、Anti-thunder
SYSTEM FEATURES
Overload Line Mode Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately
Bat. Mode Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately
Bypass Mode<40℃<=”” style=”box-sizing: border-box;”> Breaker( Load < 125%, long-term operation)
Short circuit Hold whole system
Communication interface RS232, RS485, Parallel, Intelligent Slot(SNMP card/ Relay card(optional)),
BMS (optional),EPO port, Output port, MAINTAIN-AUXSWS
PHYSICAL 
Dimension W×H×D (mm) 443×131(3U)x580 mm
Net Weight (kg) 29 31 32
ENVIRONMENT
Operating temperature 0~40℃
Storage  temperature -25℃~60℃
Humidity range 0~95% (non-condensing)
Altitude <1500m(when excess 1500m, according to GB/T 3859.2 to derating)
Noise Level <55db
STANDARDS
Safety  IEC/EN62040-1,IEC/EN60950-1
EMC  IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8