Evo Plus Tower 2000 – Long Run

Evo Plus Tower 2000 – Long Run

Part Number :EVO2000T1-MM LR

Desciption:

  • Complete protection from blackout, voltage fluctuations (overvoltages and undervoltages), lightning (with upstream arrester), frequency variations, surges, harmonics, voltage distortions
  • Recommended for Data Centers, Local Area Network (LAN ), Electro-medical, Industry processes, Virtual servers, Pellet stoves, Thermo-fireplaces, Boilers for home heating
  • Convertible format (Rack 19″ or Tower) with adjustable display
  • Hot Swap batteries
  • Intelligent slot for SNMP card o Dry Contact
  • On-Line Double Conversion technology transformerless (VFI-SS-111)
  • Active PFC circuit (0.99)
  • Compatibility with generating set
  • Battery charging system managed by microprocessor
  • Static bypass
MODEL

EVO Tower 1KVA

EVO Tower 2KVA

EVO Tower 3KVA

Capacity

1000VA/ 1000W

2000VA/ 2000W

3000VA/ 3000W

INPUT
Nominal voltage

208/220/230/240Vac

Input voltage range

110~300Vac (176~280Vac @ 100% load)

Frequency range

40~70Hz  (50/60Hz Auto-Sensing)

Power factor

≥0.99

OUTPUT
Output voltage

208/220/230/240Vac

Power factor

0.99

Voltage regulation

±1%

Output frequency Line Mode

46~54Hz or 56~64Hz

Bat. Mode

(50/60±0.1%)Hz

Crest factor

3:01

Harmonic distortion (THDv)

≤3% Linear load

≤5% Non linear load

Transfer time AC mode to Bat.Mode

0ms

Inverter to Bypass

4ms (Typical)

Output waveform

Pure Sinewave

 

EFFICIENCY
AC mode

89%

91%

92%

Battery mode

85%

87%

88%

BATTERY

Battery number

3 6

8

Charging voltage

41 VDC ± 1%

82 VDC ± 1%

110 VDC ± 1%

 Charging Current MAX

1A, 2A ,3A, 4A, 5A, 6A, 7A, 8A, 9A, 10A, 11A, 12A adjustable

INDICATORS
LED display

Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault

LCD display

Input voltage,Input frequency,Output voltage,Output frequency,Load percentage,

Battery voltage,Inner temperature& Remaining battery backup time

ALARM
Battery mode

Beeping every 4 seconds

Battery low

Beeping every second

Overload

Beeping twice every second

Fault

Continously beeping

PHYSICAL
Dimension W x D×H (mm)

352 x 145 x 213

380 x 145 x 213

390 x 145 x 213

Net weight (kg)

5.8

6.2

6.8

ENVIRONMENT
Operating temperature

0℃~40℃

Storage temperature

-25℃~55℃

Humidity range

20~95%RH @ 0~40℃ (Non condensing)

Altitude

<1500m,derating required when>1500m

Noise level

<50db at 1 Meter

STANDARDS
Safety

IEC/EN62040-1,IEC/EN62477-1

EMC

IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8